Short answer
Pick a gas insert for a fire on any night, an EPA-certified wood insert for wood heat on legal nights, or an electric unit that burns nothing. In Marin County the Air District allows only gas, electric or EPA-certified units in a permitted fireplace remodel above its cost threshold. Gas and wood inserts often need a new liner sized to the insert, so start with a Level 2 chimney inspection.
Choosing a fireplace insert for an older Marin County home
An open masonry fireplace is pleasant to sit beside and a poor way to heat a room. The EPA calls fireplaces typically very inefficient heaters that burn less cleanly than a certified wood stove, since most of their warmth disappears up the flue. Across central and southern Marin, many older houses still have the hearth they were built with: brick fireboxes in the Victorians of Gerstle Park, mid-century fireplaces in the Eichler tracts of Terra Linda, and older fireplaces in the homes tucked into Mill Valley's redwood canyons. For most of them the practical upgrade is a fireplace insert, a closed firebox that fits into the existing opening and vents up through the chimney.
There are three broad choices. A gas insert burns natural gas or propane behind sealed glass. An EPA-certified wood insert is, as the EPA puts it, a wood stove converted to fit in an existing fireplace opening. An electric unit produces heat and a flame effect with no combustion at all. Looks matter, but three local questions usually decide it: how the Bay Area's wood-smoke rules treat each fuel, what the chimney must provide to vent it, and how that chimney will hold up in the next earthquake.

How the Bay Area wood-smoke rule treats each fuel
The Bay Area Air District's wood-burning rule, Regulation 6, Rule 3, covers all of Marin and shapes the decision in two ways. First, it limits what a renovation may install. No wood-burning device of any kind may go into a newly built home, and once an owner starts a chimney or fireplace remodel that requires a building permit and costs more than the district's threshold, the only devices allowed are gas-fueled, electric or EPA-certified ones. A new open wood hearth is not on that list.
Second, it decides which nights a fire may be lit. Burning wood is prohibited on any day the Air District calls a Spare the Air alert for fine-particle pollution. Most alerts come between November and February, but wildfire smoke can bring one in other months too. A certified wood insert has to stay cold on those days like any other wood burner, and pellet units are treated as solid fuel as well. Gas and electric units fall outside the ban. The district's wood smoke rules page has current details, and our guide to Spare the Air fireplace rules explains how to check the daily status and who qualifies for an exemption.
San Rafael and county rules on wood, gas and conversions
Local codes sit on top of the regional rule, and they change with the address.
Inside San Rafael city limits, no new wood-burning fireplace may be built, but an existing one may take an EPA-certified wood insert or a permanently installed gas log unit. A basic gas log lighter, the pipe that only helps get a wood fire going, does not count as the gas option. The city also bars turning a gas fireplace into a wood-burning one and requires any new wood stove to carry EPA certification. Wood-burning fireplaces legally installed before August 17, 2007 are not restricted by the ordinance.
In unincorporated Marin, including Kentfield, Tamalpais Valley and Santa Venetia, the county building code applies instead. Its chapter on wood-burning devices does not allow a wood-burning fireplace or an uncertified wood heater to be added in new construction, additions or remodels of any size. When an existing device is remodeled or replaced, the replacement has to be a pellet heater, an EPA-certified wood heater or a gas-fueled unit, and an uncertified wood heater must be removed, made inoperable or replaced once a permitted remodel or addition exceeds 500 square feet.
Other towns, from San Anselmo to Sausalito, have their own building departments, so confirm what yours allows before ordering a unit. Wherever the house sits, California law already requires carbon monoxide alarms in any home with a fireplace or a fuel-burning appliance, so test them before the new insert is lit.
Liners and venting: what each insert asks of the chimney
An insert is only as good as the path its exhaust takes to open air. California's residential code requires masonry chimneys to be lined with material suited to the appliance they serve, in line with that appliance's listing, and the three options vent very differently.
- EPA-certified wood insert. The exhaust should run from the insert's outlet into a liner sized to match it, typically a UL 1777-listed stainless liner from the firebox to the top of the chimney. Old clay flues are often much larger than an insert's outlet, and exhaust that slows and cools in an oversized flue leaves creosote behind. The EPA notes that a certified installer will make sure the liner in a masonry chimney is installed correctly.
- Gas insert. A direct-vent unit is sealed off from the room. It takes its combustion air from outdoors and sends exhaust out through its own vent, which in a masonry chimney usually means a pair of liners, or one inside another, exactly as the manufacturer's listing specifies. A flue built for an open wood fire is usually much larger than a gas insert needs, which is why switching fuels often calls for a new, smaller liner.
- Electric unit. No flue is needed at all. The chimney still stands on the roof, though, so it needs a cap, a sound crown and a closed damper or sealed flue to keep out rain, animals and drafts.
Factory-built metal fireplaces are tested and listed as complete systems, so whether one can accept an insert depends on what the fireplace and insert manufacturers allow. In every case, a change of fuel or appliance is one of the moments when CSIA guidance points to a Level 2 chimney inspection, with a camera through the whole flue, before anything is ordered. When the flue needs one, the chimney liner becomes part of the same project.
Earthquake questions to settle before buying an insert
Central and southern Marin lie between the San Andreas Fault, which runs through West Marin from Tomales Bay to Bolinas Lagoon, and the Hayward Fault across the bay, and many chimneys in its older neighborhoods are unreinforced brick. A new liner hangs inside that masonry and depends on it. If the chimney is cracked at the roofline, leaning, or not tied to the house framing, installing an insert first and fixing the structure later can mean redoing the venting once the chimney is repaired.
The state's Seismic Safety Commission lists removing or replacing all or part of an unreinforced masonry chimney with lighter material, such as a metal flue for the upper section, among the retrofit options. That kind of rebuild pairs well with an insert, because the replacement flue can be matched to the insert's outlet at the outset. Our seismic chimney repair page covers those options, and the guide to chimney safety after an earthquake explains what to check once the ground has moved.
The fuel matters here too. An electric unit sends no exhaust through the flue, which makes it worth considering while a chimney's structural future is undecided. A gas insert brings a gas line to the hearth, so make sure everyone in the house knows where its shutoff valve is.
Matching the insert to how you use the fireplace
Once the rules and the chimney have narrowed the field, the choice usually follows from how the fireplace gets used on a Marin winter evening:
- A fire on any cold night, alert or not: a gas insert. It lights with a switch, remote or thermostat, and the burn bans do not apply to it.
- Wood heat and the ritual of a real fire: an EPA-certified wood insert. The EPA standard in force since May 15, 2020 holds new wood stoves and inserts to 2.0 grams of smoke per hour (2.5 grams when tested with cord wood), against 15 to 30 grams for older uncertified stoves, and the agency says a certified model can use up to a third less firewood. Plan around no-burn days and a yearly sweep.
- The look of a fire with no combustion: an electric unit, especially in a room that rarely needs real heat or under a chimney whose condition is still in question.
The EPA's page on choosing wood-burning appliances compares the wood and pellet options in more depth. Timing matters as well: a project that begins with an inspection and may add a liner, permit review or seismic work takes longer than picking out a unit, so start before the first cold snap. The fireplace insert installation page explains what the work involves, and you can book the first step, the inspection, through Chimney Services Pro.